Here Is Information On Hipot Tester

By Diane Bailey


The term hipot test refers to high potential or high volt voltage check. The other term for this analysis is dielectric withstand test. This is a test of electrical components done with the goal of checking the suitability of electrical insulation. The assessment is supposed to certify that there is no electrical leakage from one part to another in electric gadgets. It is the reverse of continuity test. Here are facts regarding Hipot tester.

Hipot testing is meant to be nondestructive and only to test the potency of electrical insulation. The testing uses high-voltage and is widely applied to all electrical gadgets for a certain period of time to be able to make sure that the insulating column is not marginal. The method involves applying the insulation with excessive amounts of voltage.

Determining the availability of nicked or crushed insulation in a component is part of the goal of the process. Also, the process assists in identification of corrosive or conductive contaminants, stray wire strands, and braided shielding around conductors. By using hipot testing, one can easily identify terminal spacing problems and tolerance errors in cables. Compared to operating voltage, the voltage that is normally applied in this process is two times greater.

Hipot testing is normally carried out by use of hipot analyzers. A normal tester usually connects one side to earth while the second part of the tester is connected to conductor that needs to be analyzed. In the arrangement, there are two contact points to which conductors may be connected, the ground and voltage.

In the situation there exist two contacts for which connection is needed, then a person must connect one to the ground while the other one to the voltage. This type of connection is vital. It makes sure that contacts are isolated from other forms of contacts. A small current will flow from one conductor to the other when a massive voltage is applied when the insulation placed between the two conductors is not adequate.

Even though the flow of such a small current is usually acceptable, a breakdown of solid or air insulation is not supposed to occur in any case. High voltage is usually used in these tests because it is believed that any product is usually subjected to normal day-to-day transient over voltages. As such, in case such variations in voltages occur during the day, the product is supposed to remain operational and safe.

There are several requirements that are normally checked while carrying out this evaluation. The various requirements need the voltage to get applied for a distinct amount of time. Under IEC 06950 standards, the analysis is meant to be carried out continuously for a period of one minute. Nevertheless, a typical rule is to use 110-220 percent of working voltage of the product plus a thousand volts for 1 to 2 seconds.

There also are specifications for the quantity of current that is supposed to be applied. As of now, there are several distinct varieties of testers available in the market for people to purchase. Different types of testers are designed for different categories of products. It is therefore critical to know which tester to apply for certain applications.